Windows Binding Order Prevents the Datalogic VPM Appliaction from Successfully Connecting to a Camera – Datalogic VPM Problem
Summary
This article explains how to resolve the Datalogic VPM issue where Windows binding order prevents connection to the camera.
Symptoms
- MX20 using different network interfaces (wired or wireless)
- Added USB wireless interface
Explanation
When deploying an MX20, we added a wireless USB NIC. By doing this, Windows put the wireless network adapter as #1 on the Windows binding list. Therefore, when trying to connect VPM to a camera, it defaulted to the wireless and failed to find the cameras.
Solution
Check the binding order of different network adapters on the Processor/PC and adjust so the cameras (CAM1, CAM2, etc.) and the internal network (INT1) are first on the list.
Additional Comments