The installation of TEKLYNX CENTRAL failed with a message “Unable to connect to UMSS server. It is not available”. This article explains the problem and offers a solution to this issue.
Symptoms
During the installation process of TEKLYNX CENTRAL, the installation displays an error message window with the message “Unable to connect to UMSS server. It is not available” and the installation of the software failed.

Explanation
The error occurred because UMSS Service TkxSvr Servers Service did not start.
When checking the error events in the Windows Event Viewer, there should be entries with event # 7009 during the time of the software installation. The event will point to the fact that the service TkxSvr Servers Service did not start because the “timeout was reached (30000 milliseconds) …”. In short, the service took too long to start. There can be many possible causes for this; server configuration or no access to Internet to name two.
Solution
Since this is a timeout issue, we can resolve this situation by increasing the timeout value from 30000 milliseconds (30 seconds) to 60000 or 120000 (1 minute or 2 minutes).
Instructions on how to do this: Increase Time Out Value for Service Start Up – Windows Instructions
Author
Related Articles
- Loftware Redirect Print to PDF action using multiple printer seats
- License is failed – TEKLYNX CENTRAL Error Message
- Loftware Web Designer vs Desktop Designer
- Loftware Workday API Splitting Print Jobs
- Planning a BarTender Server Migration and Upgrade – BarTender Instructions Article
- Deciding on an In-Place Upgrade, Test Server, or Migration – BarTender Reference Article