This article explains the cause behind the error message “The application has failed to start because its side-by-side configuration is incorrect“ when starting TkxSvrService service in TEKLYNX CENTRAL 5.0 as well as the resolution.
Explanation
The following message appeared when a user tried to start TkxSvrService manually using the command line – SC start TkxSvrService.
[SC] StartService FAILED 14001:
The application has failed to start because its side-by-side configuration is incorrect. Please see the application event log or use the command-line sxstrace.exe tool for more detail.
An internet search identifies the issue as a damaged .NET or Visual C++ installation and recommends that user reinstall or repair the software.
However, in the context of TEKLYNX CENTRAL, this may not be the actual cause. In the incident that lead to this article, there was a problem with the Tkx.TkxSvr.ServerService.exe.Config file. This file is typically located in C:\Program Files (x86)\Teklynx\TkxSvrServers folder. The user manually edited this file and the XML syntax was incorrect.
Solution
After the XML syntax was corrected, the service started normally without any further error messages.
Author
Related Articles
- Loftware Redirect Print to PDF action using multiple printer seats
- License is failed – TEKLYNX CENTRAL Error Message
- Loftware Web Designer vs Desktop Designer
- Loftware Workday API Splitting Print Jobs
- Planning a BarTender Server Migration and Upgrade – BarTender Instructions Article
- Deciding on an In-Place Upgrade, Test Server, or Migration – BarTender Reference Article