“Retrieving the COM Class Factory for Component with CLSID…” – CODESOFT Error
Target Audience: IT Manager
Article #: 12548
Summary
When BACKTRACK attempts to launch CODESOFT, the launch fails and the user gets a message reading “Retrieving the COM class factory for component with CLSID {3624B9C0-9E5D-11D3-A896-00C04F32E22} failed due to the following error: 80080005 Server execution failed (Exception from HRESULT: 0x80080005 (CO_E_SERVER_EXEC_FAILURE)).”

This article explains what happens and the procedure to resolve the underlying issue.
Explanation
Simply put, CODESOFT is unable to find a critical .exe file during launch.
In this particular case, we found that system security software such as Carbon Black or Symantec Endpoint Protection, is blocking the computer’s access to the Lppa.exe file located in the folder C:\Program Files (x86)\Teklynx\CODESOFT 2021.
Quick Fixes
The solution is straightforward.
- Open your security software’s whitelist/blacklist settings
- Add the Lppa.exe file, its folder or the entire PC to the whitelist to prevent it from blocking CODESOFT’s access to the file.
Additional Comments
Issue found: Windows 10, CODESOFT 2015.
If you need further assistance, please contact us.
Author
Related Articles
- Loftware Redirect Print to PDF action using multiple printer seats
- License is failed – TEKLYNX CENTRAL Error Message
- Loftware Web Designer vs Desktop Designer
- Loftware Workday API Splitting Print Jobs
- Planning a BarTender Server Migration and Upgrade – BarTender Instructions Article
- Deciding on an In-Place Upgrade, Test Server, or Migration – BarTender Reference Article